Photonic Edge Photonic Edge Inc. 日本語
Solutions›Microwave & Millimeter-Wave Devices›Mixers for Spectrum Analyzers
MICROWAVE & MM-WAVE DEVICES / MIXERS FOR SPECTRUM ANALYZERS

Mixers for Spectrum Analyzers — V- to J-band (50–330 GHz)

Mixers (spectrum analyzer extenders) that connect to the spectrum analyzer you already own and extend its measurable frequency range into the millimeter-wave and sub-terahertz bands. Available for each band from V to J, covering 50–330 GHz. With an analyzer that reaches a few tens of GHz, you can observe signals in the 300 GHz band without buying expensive dedicated instruments.

Spectrum analyzer extenderEach band from V to JHarmonic order from 2ndLO doubler-amplifier available
A mixer under evaluation: a small gold block connected to a waveguide and a coaxial cable.
J-band mixer under evaluation (the gold block). The 220–330 GHz signal enters from below through the waveguide; the single coaxial connector on top carries both the LO input and the IF output.
Frequency coverage50–330GHzEach band from V to J
LO input+13 to +19dBm
RF input (max.)+10dBm
  • Make use of the analyzer you have: just connect to the analyzer's external-mixer port to observe spectra in the millimeter-wave and sub-terahertz bands
  • Harmonic order from the 2nd: choose the order to suit the LO frequency your analyzer or signal generator can provide
  • Also works as a harmonic mixer: with a part that separates LO and IF (a diplexer), it can be used in a receiver chain driven by a signal generator
Spectrum analyzer screen. Center 286.005 GHz, span 10 kHz. A single sharp peak at the center; the peak reads −23 dBm and the noise floor is around −85 dBm.
Analyzer screen showing a 286 GHz signal. Observed with our J-band mixer connected to a Rohde & Schwarz spectrum analyzer. "ExtMix J" at the upper left indicates that the analyzer is set to use an external mixer (J-band).
MEASURED

Observation example: spectrum at 286 GHz

A single sharp peak about 60 dB above the noise floor
  • Center at 286.005 GHz: span 10 kHz, resolution bandwidth (RBW) 10 Hz
  • About 60 dB between peak and noise: on the screen, the peak reads −23 dBm and the noise floor is around −85 dBm
  • A single line even at 10 Hz resolution: no noticeable unwanted components appear within the displayed range (center ±5 kHz)

A 286 GHz signal, which the analyzer alone cannot measure, can be observed directly on its screen like this once the mixer is connected.

01

Supported Bands and Common Specifications

The housing and the internal board design are common to all bands; only the size of the RF input waveguide differs from band to band.

BandFrequencyRF input waveguide
V-band50–75 GHzWR-15
E-band60–90 GHzWR-12
W-band75–110 GHzWR-10
D-band110–170 GHzWR-6
G-band140–220 GHzWR-5
J-band220–330 GHzWR-3
Common specifications
LO input power+13 to +19 dBm
RF input powerUp to +10 dBm
Harmonic orderUsable from the 2nd (chosen to suit the LO frequency)
LO/IF portOne coaxial connector (2.92 mm) shared by LO input and IF output
SizeApprox. 24 × 20 × 20 mm (J-band example; excluding connector and waveguide)
02

Conversion Loss versus Frequency

Harmonic orders from the 2nd upward can be used. In the D- and J-bands, however, a low order requires a high-frequency LO, which takes substantial equipment to provide. The curves below are for orders at which the LO is easy to prepare: the 16th for D-band and the 20th for J-band.

D-BAND

D-band (110–170 GHz)

16th harmonic: conversion loss approx. 45–57 dB
Conversion loss versus frequency of the D-band mixer: about 46 dB at 110 GHz, about 56 dB near 150 GHz, and about 50 dB at 170 GHz.

The LO is 6.9–10.6 GHz (RF frequency ÷ 16).

J-BAND

J-band (220–330 GHz)

20th harmonic: conversion loss approx. 41–56 dB
Conversion loss versus frequency of the J-band mixer: about 53 dB at 220 GHz, about 41 dB near 290 GHz, and about 52 dB at 330 GHz.

The LO is 11–16.5 GHz (RF frequency ÷ 20).

Measured in-house. Loss increases toward the bottom of the vertical axis. Scatter among repeated measurement points has been smoothed into a representative curve; most of the scatter comes from fluctuations in the power of the signal source used for the measurement.

03

Works with the Spectrum Analyzer You Have

Whether a mixer can be used depends on the frequency and power of the LO that the analyzer provides for external mixing. For models whose LO frequency is low or whose LO power is insufficient, we supply a "doubler-amplifier" that doubles the LO frequency and amplifies it.

Manufacturer and representative modelsLO output for external mixingConnection to our mixer
Keysight X-Series
PXA, MXA, EXA, etc.
3.75–14 GHzDirect connection (LO output and IF input share one port)
Rohde & Schwarz FSW
FSW43, etc.
7.65–17.45 GHz, +15.5 dBmDirect connection
Agilent 8560EC Series
8563EC, 8564EC, 8565EC
3.0–6.8 GHz, +16.5 dBmDoubler-amplifier supplied (LO raised to 6–13.6 GHz)
Agilent ESA-E Series
E4407B
2.9–7.1 GHz, +13 to +17.5 dBmDoubler-amplifier supplied
Agilent PSA Series
E4440A, E4446A, E4448A
Approx. 3–7 GHzDoubler-amplifier supplied

Analyzer specifications are representative values based on each manufacturer's published documents and vary by model and option. Tell us your model and we will propose the harmonic order and configuration.

04

Also Usable as a Harmonic Mixer

The mixers are not limited to spectrum analyzers. With a diplexer (available separately) to split LO and IF, and a signal generator as the LO, they serve as harmonic mixers that convert millimeter-wave and sub-terahertz signals to a lower frequency.

RF

Millimeter-wave signal

Fed to the mixer through a waveguide

MIXER

Mixer

Mixes with a harmonic of the LO and converts to a lower frequency

DIPLEXER

Diplexer

Separates the LO and IF that travel on a single coaxial line

LO / IF

Signal generator and receiver

LO from a signal generator; IF to a receiver or SDR

As an example of this configuration, we receive the signal of a 76 GHz automotive radar with a horn antenna and a mixer and analyze it with an SDR (Millimeter-Wave Radar Analysis Tool, in Japanese).

05

Evaluation with Photonically Generated Signals

In the D- and J-bands, the signal sources available for evaluation are themselves limited. We generate millimeter-wave and sub-terahertz waves by converting the frequency difference between two laser beams into a radio wave with a high-speed photodiode (photomixing), and use them to evaluate the mixers. The J-band curve above was measured this way.

Conversion loss of the D-band mixer measured with an electronic source and with a photonically generated signal. The two curves largely overlap.
D-band mixer measured with two kinds of source. Gray is the electronic source; pink is the photonically generated signal. They agree well above 140 GHz.
  • A clean spectrum without unwanted components: signals made with multipliers contain components at frequencies other than the intended one (spurious). Photonically generated signals do not, which suits them to testing receiver-side components
  • One mechanism up to high frequencies: simply changing the frequency difference between the lasers tunes the signal continuously from D-band to J-band
  • An application of our measurement technology: photonics-based millimeter-wave and terahertz measurement is the technology our company started from

Company and product names mentioned are trademarks or registered trademarks of their respective owners.

Talk to us about anything high-frequency.

Contract R&D, custom measurement instruments, software development, joint research — we work in whatever form suits your project.

Contact Us