- Make use of the analyzer you have: just connect to the analyzer's external-mixer port to observe spectra in the millimeter-wave and sub-terahertz bands
- Harmonic order from the 2nd: choose the order to suit the LO frequency your analyzer or signal generator can provide
- Also works as a harmonic mixer: with a part that separates LO and IF (a diplexer), it can be used in a receiver chain driven by a signal generator

Observation example: spectrum at 286 GHz
A single sharp peak about 60 dB above the noise floor- Center at 286.005 GHz: span 10 kHz, resolution bandwidth (RBW) 10 Hz
- About 60 dB between peak and noise: on the screen, the peak reads −23 dBm and the noise floor is around −85 dBm
- A single line even at 10 Hz resolution: no noticeable unwanted components appear within the displayed range (center ±5 kHz)
A 286 GHz signal, which the analyzer alone cannot measure, can be observed directly on its screen like this once the mixer is connected.