Components that convert millimeter-wave and sub-terahertz signals to a lower, easier-to-handle frequency by mixing them with a harmonic of the LO (local oscillator). We cover 10 GHz through J-band (330 GHz). Without preparing a high-frequency LO, a signal generator reaching only a dozen or so GHz is enough to receive signals in the 300 GHz band.
The lineup by RF frequency. There are two types, depending on which multiple of the LO frequency the signal is mixed with.
Harmonic mixers (use a high-order harmonic of the LO) Subharmonic mixers (use twice the LO frequency)
For V-band and above, the body is the same as our mixers for spectrum analyzers. Fitted with a diplexer (a part that separates LO and IF), it is used as a harmonic mixer. The letters in the bars are band names (V-, E-, W-, D-, G- and J-band). Frequencies not listed here can be designed to your requirements.
Conversion loss versus frequency when a 220–330 GHz signal is mixed with the 20th harmonic of the LO. Harmonic orders from the 2nd upward can be used; the values shown are for the 20th, for which the LO is easy to prepare.

Measured in-house. Loss increases toward the bottom of the vertical axis. Repeated measurement points have been smoothed into a representative curve.
| J-band harmonic mixer | |
|---|---|
| RF | 220–330 GHz (WR-3 waveguide) |
| LO | 11–16.5 GHz (20th harmonic), +13 to +19 dBm |
| Harmonic order | Usable from the 2nd |
| RF input power | Up to +10 dBm |
| LO/IF port | Shared coaxial connector (2.92 mm); a diplexer separates LO and IF |
| Size | Approx. 24 × 20 × 20 mm (excluding connector and waveguide) |
D-band (110–170 GHz) performance is shown on the mixers for spectrum analyzers page.



Using a mixer in practice requires a circuit to supply the LO and a circuit to amplify the converted signal. We build not only the mixer itself but everything around it.
In the microwave bands, we also design boards that mount commercial RF chips — smaller than waveguide components and easier to produce in quantity.
We also build the multipliers and amplifiers that generate the LO for the mixer. They can be inserted when your signal generator falls short in frequency or power.
We can combine an oscillator (PLL), LO driver, IF amplifier and other parts into one unit and deliver it as a complete transmitter or receiver.
Contract R&D, custom measurement instruments, software development, joint research — we work in whatever form suits your project.